RO Membrane Cleaning Indonesia

Reverse Osmosis (RO) application in Indonesia has been started since many years ago from sea water desalination until pharmaceutical industries and RO membrane cleaning itself is one of the most critical part need to be done when you face performance issue, as it mostly caused by fouling and scaling.

Fouling itself has two possible form, bio fouling or mechanical fouling (foreign material brought along with the raw water), which will blocked the surface of the membrane and giving problem on your RO process. Scaling normally happened due to formation of soluble salt such as calcium carbonate and calcium sulfate, those salt are deposits and accumulate hence create layers which will blocked your membrane as well.

When do you need to clean the RO Membrane?

The indicator could be seen either from reduce of your product flow or increase of your pressure difference before and after the Reverse Osmosis equipment. Of course you have to check your pumps and water source to make sure it has no problem there, if you feel uncertain about your real problem, just send us message here and we will try our best to help you.

Why Artha Inti?

Different water source at different location having different problem and solution, therefore to consult first your typical process is necessary, how much flow you need and which pH level is optimum for the cleaning procedure, it really depend on your type of fouling and scaling. Cleaning of your membrane will be more effective if it is customised based on your problem, most often the problem getting worse due to wrong chemical cleaning composition given to your system.

PT. Artha Inti Manunggal has been handled many kind of situation and case of cleaning membrane RO in different industry application. We always try to give the most optimum cost solution for our customers. So, just let us know your need and our customer service will discuss further for free consultation prior to decide the most optimal solution for your need.

call us here…

021-29405555

PT. Artha Inti Manunggal

Jl. Tanjung Pura Raya No.3 Kalideres – Jakarta Barat
Fax: +6221 5407613

or, email us your problem here…

Yes, I need support!

Our unique solution of Reverse Osmosis Membrane Cleaning consist of:

Low pH Membrane Cleaner

Overton 43 removes calcium carbonate scale and metal hydroxide colloids without damaging sensitive polyamide composite membrane elements.

It is to be used after the system shows a sign of performance loss or as a preventative cleaning.

High pH Membrane Cleaner

Overton 44 removes biological, organic and colloidal foulants without damaging sensitive polyamide composite membrane elements.

It is to be used after the system shows a sign of performance loss or as a preventative cleaning.

 

N

Biomate for Reverse Osmosis

Overton 40 is used to reduce slime that grows inside Reverse Osmosis membrane. Treatment programme for this uses a combination of Overton 40, Overton 43 or Overton 44. This programme will also reduce the frequency of cleaning.